Details
|
Type 400/100 KW
|
Over all Data Cut in windspeed Cut out Windspeed Rated windspeed Survival Windspeed Tip Speed Rotor Revolutions Hub height (optional) Nacelle tiltangle Regulation
|
Approx. 4m/s Approx. 25m/s 15 m/s 60m/s at 2 sec gust 58/39 m/s 35.7 / 23.8 rpm 36 m 5 Degrees Stall
|
Gear Box Type Gear Ratio No.of steps
|
Helical 1:42 2
|
Generator Rated Power Output Type
Voltage Revolutions Frequencies |
400/100 KW Asynchronous 3phase
690V 1500/1000 rpm 50 Hz |
Tower Type Height (Optional) Material Sections Ladder Nacelle frame
|
Tubular 34.7 m Steel plate 4 Inside the tower Hot Sprayed galvanised welded steel plate frame |
Rotor No. of blades Diameter Swept area Material
Pitch Power Regulation
|
3 31 m 755 sq.m Polyester reinforced Fiberglass
Fixed Stall
|
Brake System Aerodynamics Mechanical Yaw System
|
Leading tip spoiler Failsafe disc brake Siewing system with Gearmotors yawing
|
| Controls |
Micro Processor based |